Medical devices repair, Ultrasound machine & transducer, Flexible &Rigid endoscope and Dynamic system

Sales & Support
Request A Quote - Email
Select Language
English
Русский
العربية
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsParts for Camera System

High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head

High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head

High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head
High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head

Large Image :  High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head Get Best Price

Product Details:
Brand Name: OLYMPUS
Model Number: CH-S400-XZ-EA
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Accept Negotiation
Packaging Details: Standard Package
Payment Terms: T/T
Detailed Product Description
Brand: Olympus Model: CH-S400-XZ-EA
Condition: Working In Excellent Condition Series: Camera Cable
Cable Length: 3.0 Meters Transmission Technology: High-speed Optical-Fiber Transmission
Sterilization Compatibility: Autoclavable MOQ: 1 Piece
Package: Carton / Standard Export Packing Transportation: DHL, FedEx, UPS, Etc.
In Stock: Yes Price: Accept Negotiation

High-performance Cable For OLYMPUS CH-S400-XZ-EA Camera Head

 

 

► Brief Description

The OLYMPUS CH-S400-XZ-EA is an advanced 4K Ultra-High-Definition (UHD) autoclavable camera head utilized in minimally invasive laparoscopic and endoscopic surgeries. Its integrated cable assembly acts as the vital lifeline connecting the ergonomic camera head directly to the Olympus OTV-S400 video processor. Engineered with optical-fiber transmission technology, this cable delivers uncompressed, real-time 4K visual data while ensuring maximum durability through rigorous hospital sterilization cycles.

 

 

►Features

 

  • Ultra-High-Speed 4K Transmission (Zero Latency):Leveraging optical-fiber pathways, the cable transfers massive 4K video data packages instantaneously, eliminating visual delay and ensuring real-time surgical accuracy.

  • Total Electromagnetic Interference (EMI) Immunity:Optical fiber isolation protects the video feed from external electrical noise or interference generated in the operating room, maintaining a stable and static-free image.

  • High Durability & Sterilization Resilience:Built to withstand harsh clinical environments, the cable and its outer jacket are fully compatible with high-temperature steam autoclaving (a key feature of the "-EA" variant) as well as standard low-temperature gas sterilization methods.

  • Support for Advanced Imaging Modalities:Seamlessly relays data required for advanced visualization features, such as One-Touch Auto Focus, electronic magnification/zoom, and Narrow Band Imaging (NBI) for enhanced capillary and tissue differentiation.

  • Ergonomic Flexibility:Despite its heavy-duty medical shielding, the 5.1 mm diameter cable remains lightweight and flexible, minimizing wrist drag and hand fatigue for surgeons during lengthy procedures.

 

 

► Specification

 

Brand Olympus
Model CH-S400-XZ-EA
Condition Working in excellent condition
Series Camera Cable
Cable Length 3.0 meters
Transmission Technology High-speed Optical-Fiber Transmission
Sterilization Compatibility Autoclavable
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

 

 

► FAQ

 

What should I do if the monitor displays "No Image" or a communication error (e.g., Error E224) when connecting the camera head?

  • Answer:

    1. Check the video connector end to ensure it is firmly and correctly plugged into the Olympus OTV-S400 processor.

    2. Inspect the connector pins for moisture, bending, or debris. Dry or clean them thoroughly before reconnecting.

    3. If the error persists, it may indicate internal optical fiber damage or a faulty wiring harness due to excessive pulling or sharp bending. Send the unit for technical evaluation.

 

What are the main signs of internal cable damage during daily handling?

  • Answer: Common indicators of a compromised cable include:

    • Intermittent signal loss, flickering, or rolling lines on the 4K monitor when the cable is moved.

    • Communication errors or failure to recognize the camera head upon startup.

    • Visible outer sheath cracking, micro-punctures, or localized bulging along the 3-meter length.

 

 

► More service

Spare parts for Karl Storz camera head, such as CCD, cable, cover, sheath/strain relief, etc.
Camera system brand by OLYMPUS, WOLF, STORZ, Stryker, Smith&Nephew, ScanMed, etc.

Main models of camera head:
5502, 5506, 5507, 5509, 5512, 5516, 5525, 5550, etc by Wolf;
OTV-S4, OTV-S5, OTV-SX2, OTV-SC, OTV-S6, OTV-S7, CV-165, etc by Olympus;
22201020, 20242020, 22202022, 20212020, etc by Storz Image 1 HUB HD;
888i, 988i, 1088/1088HD, 1188/1188HD, 1288/1288HD, 1488/1488HD, 1588/1588HD, 1688/1688HD, etc by Stryker;
460P, 560P, ED-3, 325Z, 350, etc by Smith&Nephew.

► About Us

 

JDP is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

 

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

Contact Details
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED

Contact Person: Mr. Maud

Tel: 13922729804

Send your inquiry directly to us