Medical devices repair, Ultrasound machine & transducer, Flexible &Rigid endoscope and Dynamic system

Sales & Support
Request A Quote - Email
Select Language
English
Русский
العربية
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsParts for Rigid Endoscope

Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit

Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit

Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit
Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit

Large Image :  Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT Roller Pump Unit Get Best Price

Product Details:
Place of Origin: China
Brand Name: JDP
Model Number: 26331020
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Accept Negotiation
Packaging Details: Standard Package
Payment Terms: T/T,
Detailed Product Description
Brand: KARL STORZ Model: 26331020
Condition: Brand New Series: Irrigation / Distension Tubing Set
Tubing Material: DEHP-free Medical-grade PVC And Silicone MOQ: 1 Piece
Package: Carton / Standard Export Packing Transportation: DHL, FedEx, UPS, Etc.
In Stock: Yes Price: Accept Negotiation

Brand New Irrigation / Distension Tubing Set For KARL STORZ 26331020 HAMOU ENDOMAT

 

 

► Brief Description

The KARL STORZ HAMOU ENDOMAT (Model 26331020) irrigation/suction tubing set (commonly referred to as distension tubing or pump cassette/tubing set) is a dedicated fluid-delivery consumable designed for hysteroscopic distension and endoscopic irrigation. Engineered for seamless integration with the HAMOU ENDOMAT SCB roller pump unit, it ensures controlled, continuous fluid flow and accurate intrauterine pressure monitoring during diagnostic and operative hysteroscopy.

 

 

►Features

 

  • Controlled Fluid Delivery: Transmits irrigation/distension media (e.g., normal saline, glycine, or sorbitol/mannitol depending on energy modality) smoothly from the fluid bag to the hysteroscope inflow channel via peristaltic roller action.

  • Real-Time Pressure Monitoring: Relays hydraulic pressure back to the 26331020 control unit so the pump can automatically regulate flow rate and maintain target intrauterine distension pressure (typically adjustable up to 150–200 mmHg depending on system settings).

  • Overpressure Safety Protection: Enables immediate pump pause or pressure-relief response if intrauterine pressure exceeds preset safety thresholds, reducing the risk of excessive fluid intravasation.

  • System Recognition & Seal Integrity: Features a keyed cassette/collar or sensor interface that aligns securely with the pump housing to prevent slippage, air entrainment, or fluid leakage during procedures.

 

► Specification

 

Brand KARL STORZ
Model 26331020
Condition Brand new
Series Irrigation / Distension Tubing Set
Tubing Material DEHP-free medical-grade PVC and silicone
MOQ 1 Piece
Package Carton / Standard Export Packing
Transportation DHL, FedEx, UPS, etc.
In Stock Yes
Price Accept Negotiation

 

 

 

►FAQ

 

 

What is the difference between single-spike and dual-spike tubing sets?A:

  • Single-spike tubing sets connect to one fluid bag at a time and are suitable for shorter diagnostic or minor operative procedures.

  • Dual-spike (Y-type) tubing sets allow two irrigation bags to be hung simultaneously with integrated pinch clamps, enabling uninterrupted fluid switching during longer operative hysteroscopy procedures without introducing air into the line.

Why does the pump fail to deliver fluid or show zero flow even though the rollers are turning?A: Common causes include:

  • Unopened clamps or air vents: Verify that the roller clamp on the tubing and the air-venting cap on the fluid bag spike are open.

  • Misaligned pump segment: The silicone tubing section may have slipped out of the roller track; release the rollers and re-seat the collar.

  • Kinked line or empty fluid bag: Inspect the entire path from the fluid bag to the hysteroscope inflow stopcock.

 

 

Why is the unit displaying abnormally high irrigation pressure or triggering an overpressure alarm?A:

  • Closed inflow stopcock: Check that the inflow valve on the hysteroscope sheath is fully open.

  • Blocked outflow or debris: Tissue fragments or blood clots in a narrow sheath channel can restrict flow and spike line pressure.

  • Pressure sensor issue: Ensure the pressure-sensing dome/membrane is properly seated and free of fluid/moisture on the sensor side.

  • Hydrostatic height offset: Confirm the fluid bag is hung at the standard recommended height relative to the pump and patient level.

 

► More service

 

Spare parts for Rigid Endoscope:
 

Rod lens,Objective lens,Rings,Glass,Eyepiece & Cover,Outer tube & Inner tube,Fiber,etc.

 

 

► About Us

 

JDP is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.

 

Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.

 

Contact Details
JDP MEIDICAL TECHNOLOGY (H.K.)CO.,LIMITED

Contact Person: Mr. Maud

Tel: 13922729804

Send your inquiry directly to us